menu

Izjava o svojstvima

N2XH

XLPE/HFFR power cable with special fire performance 0,6/1 kV

Electrical power, distribution and control cables are specifically designed for use in industrial facilities, power plants, hotels, hospitals, schools, tunnels, data centers, and other electrical installations where high electrical and thermal loads are expected. They offer a high level of fire protection, making them ideal for environments where safety and reliability are critical. The cables can be installed on cable trays, beneath plaster, within walls, and in concrete structures. However, they are not suitable for direct underground installation without additional external protection against mechanical stress or water ingress.

Standard:

VDE 0276-604

Nominal voltage:

0,6/1 kV

Temperature application:

  • at installation: od -5°C do +50°C
  • fixed: od -30°C do +90°C

Insulation/sheath:

XLPE/HALOGEN-FREE FLAME-RETARDANT POLYOLEFIN

Construction:

  • conductor: Cu class 1 or class 2 acc. to VDE 0295 (IEC 228/HD 383), solid or stranded
  • insulation: XLPE type 2XI1 according to VDE 0276-604
  • core colours: acc. to VDE 0293 (=HD 186)
  • type -O: without yellow/green core
  • type -J: with yellow/green core
  • cores: concentrically stranded
  • filling: flame-retardant halogen-free filling
  • sheat: polyolefin type HM4 according to VDE 0276-604

Sheath colour:

black

Fire classification:

Single core sheathed (unarmoured): B2ca-s1b,d1,a1

Multicore sheathed (unarmoured) round conductor: Cca-s1b,d2,a1

Multicore sheathed (unarmoured) sector conductor: B2ca-s1b,d0,a1

Flame retardance: 

EN 60332-1-2

EN 60266-2-4

Minimal bending radius: 

multi-core – ca. 15-18x diameter

Application:

Power, distribution and control cables in industrial plants, power stations, hotels, hospitals, schools, tunnels,  data centers and other electrical plants in which high  electrical and thermal strain is expected and requires a greater degree of fire protection. For the installation on cable trays, under plaster, in masonry and in concrete. It is not suitable for direct burial without external protection against mechanical stress or water.
 

Electrical power, distribution and control cables are specifically designed for use in industrial facilities, power plants, hotels, hospitals, schools, tunnels, data centers, and other electrical installations where high electrical and thermal loads are expected. They offer a high level of fire protection, making them ideal for environments where safety and reliability are critical. The cables can be installed on cable trays, beneath plaster, within walls, and in concrete structures. However, they are not suitable for direct underground installation without additional external protection against mechanical stress or water ingress.